FM GLOBALAPPROVED
UL LISTEDCERTIFIED
NFPA 11COMPLIANT
NFPA 13COMPLIANT
ISO 9001CERTIFIED
API 2030STANDARD

Zero Incidents
Isn't Luck.
It's Engineering.

FireShield engineers suppression systems for the facilities where failure isn't an option — refineries, chemical processing plants, and manufacturing floors protecting assets valued at $200M+.

340+
Facilities Protected
<8s
Avg. Activation
100%
NFPA Compliant
Industrial refinery facility at dusk showing complex pipe networks and steel structures
System Status
Pressure175 PSI
Coverage12,400 m²
AgentAFFF 3%
All Systems Nominal
FM GLOBAL APPROVEDNFPA 11 · NFPA 13 · NFPA 15 · NFPA 16UL LISTED COMPONENTSISO 9001:2015 CERTIFIEDAPI 2030 STANDARDZERO DOWNTIME INSTALLATIONSAFFF · DRY CHEMICAL · CO₂ · CLEAN AGENTFOAM DELUGE · SPRINKLER · DELUGE SYSTEMSFM GLOBAL APPROVEDNFPA 11 · NFPA 13 · NFPA 15 · NFPA 16UL LISTED COMPONENTSISO 9001:2015 CERTIFIEDAPI 2030 STANDARDZERO DOWNTIME INSTALLATIONSAFFF · DRY CHEMICAL · CO₂ · CLEAN AGENTFOAM DELUGE · SPRINKLER · DELUGE SYSTEMS
Scenario 01 / Thermal Event

Thermal Runaway in Lithium Storage Bay

A single cell failure in a 2,400-module battery rack initiates cascading thermal propagation. Conventional water suppression accelerates the reaction. Standard sprinkler heads activate 47 seconds too late.

Estimated Loss$180M+Energy Storage / EV Manufacturing
Engineered Response

Clean Agent Suppression + Thermal Detection Matrix

Multi-zone FM-200 or Novec 1230 deployment triggered by infrared thermal imaging at 62°C threshold — 22 seconds before runaway escalates. Zero water contact. Zero residue. Facility re-entry in under 4 hours.

Clean agent suppression system nozzles in a modern industrial facility
Detection Threshold62°C / 144°F
Agent Discharge≤ 10 seconds
Coverage Density8.5% vol. concentration
NFPA StandardNFPA 2001
Re-entry Time< 4 hours
Activation Time< 10s
Scenario 02 / Vapor Ignition

Vapor Cloud Formation at Loading Rack

Hydrocarbon vapor accumulation at a crude oil loading rack reaches LEL in 90 seconds during a transfer pump seal failure. A single static discharge ignites a VCE capable of overpressure damage across 400 meters.

Blast Radius400mPetroleum Refinery / Tank Farm
Engineered Response

Foam Deluge System with Vapor Suppression Blanket

Pre-piped AFFF 3% foam deluge activates within 6 seconds of flammable gas detection, blanketing the spill surface with a 25mm foam layer that cuts off oxygen and halts vapor generation. Flow rate engineered to NFPA 11 Chapter 5 specifications.

Industrial tank farm with fire suppression foam deluge system infrastructure
Foam TypeAFFF 3% × 3% AR
Application Rate6.5 L/min/m²
Activation6 seconds post-detection
NFPA StandardNFPA 11 / API 2030
Suppression Time< 45 seconds
Activation Time6s
Next Step

Is Your Facility Exposure-Ready?

A FireShield site assessment identifies suppression gaps, maps compliance exposure, and delivers a prioritized remediation plan — at no cost.

Request a Site Assessment
Field Results

Proven Under
Real Conditions.

Every project below was completed without a single day of unplanned downtime. Numbers are from post-implementation audits.

Petroleum Refinery

Gulf Coast Crude Processing Facility

Beaumont, TX
Challenge

Aging deluge system on 14 crude storage tanks — last inspection 2018, NFPA 11 non-compliant, FM Global renewal at risk.

Outcome

Full foam deluge replacement across 14 tanks. FM Global approval renewed. Insurance premium reduced by 31%.

31%
Insurance Savings
< 40s
Suppression Time
0 days
Downtime
Chemical Processing

Specialty Chemical Manufacturer

Baton Rouge, LA
Challenge

Reactor bay CO₂ system failed annual NFPA 12 inspection. Production halt order issued. 72-hour remediation window.

Outcome

Emergency system replacement completed in 58 hours. NFPA 12 compliance restored. Production resumed on schedule.

58 hrs
Remediation Time
Compliant
NFPA 12
$4.2M
Revenue Protected
Food Processing

Large-Scale Fryer Line Facility

Fresno, CA
Challenge

Grease fire propagation risk across 240m continuous fryer line. Previous system inadequate for Class K classification.

Outcome

Custom wet chemical suppression system with 0.8-second fusible link detection across all 12 fryer zones.

0.8s
Detection Speed
12
Zones Covered
Full
Class K Rating
Automotive Manufacturing

EV Battery Assembly Plant

Detroit, MI
Challenge

New facility greenfield spec: thermal runaway suppression for 3 battery module assembly lines with clean-room constraints.

Outcome

Novec 1230 clean agent system with IR thermal matrix. Zero residue. Clean-room integrity maintained post-activation.

Novec 1230
Agent Type
< 8s
Activation
Zero
Residue
Authority & Compliance

Every Certificate.
Current.

Our approvals aren't framed on a wall — they're embedded in every system spec, installation record, and inspection tag we issue.

FM GLOBAL2024
Factory Mutual Approval
FM 5130 / FM 5131
Foam Suppression Systems
UL LISTED2024
Underwriters Laboratories
UL 162 / UL 199
Foam Equipment & Sprinklers
NFPA 112021
Low-, Med- & High-Expansion Foam
NFPA 11:2021
Tank Farm & Spill Protection
NFPA 132022
Sprinkler System Installation
NFPA 13:2022
Commercial & Industrial
NFPA 20012022
Clean Agent Extinguishing
NFPA 2001:2022
Clean Agent Systems
ISO 90012023
Quality Management System
ISO 9001:2015
Design, Supply & Installation
API 20302024
Application of Fixed Systems
API 2030:2005
Petroleum Storage Tanks
NFPA 122022
Carbon Dioxide Extinguishing
NFPA 12:2022
CO₂ Suppression Systems

All certifications current as of February 2026. Full documentation packages available for insurance underwriters, facility auditors, and procurement review. Contact our compliance team for certificate copies.

Start Here

Two Ways to
Reduce Your Exposure.

Whether you're ready for a full site walk or just starting your compliance audit, we have the right entry point.

No-Cost Site Assessment Request

Your information is never shared. Assessment is complimentary.